Overview

Product Series Description

COMMERCIAL STORAGE TANKS
Meet ASHRAE 90.1b (current edition)
80, 120 and 200 GALLON MODELS

Features:
2″ Non-CFC foam insulation.
Glass lined steel tank—Elbi’s Ultonium™ lining is applied
to the interior surface of the steel providing a tough wear
resistant lining which minimizes the effects of high
temperature hot water.
Factory installed dielectric fittings—no dielectric fittings or
unions needed.
Side T&P valve opening.
Two magnesium anode rods—for more even distribution of
corrosion protection and longer service life.
Hand hole cleanout—for removal of accumulated lime and
sediment deposits.
Brass drain valve.
Five year limited warranty on steel tank—heavy gauge
steel automatically formed, rolled and welded to assure a
continuous seam for glass lining. Each tank is triple tested to
insure quality.
One year limited warranty on parts.

Features & Benefits

Insulation 2" Non-CFC foam insulation
Glass Lined Steel Tank Elbi's Ultonium™ lining is applied to the interior surface of the steel providing a tough wear resistant lining which minimizes the effects of high temperature hot water.
Factory installed dielectric fittings No dielectric fittings or unions needed.
Valve Opening Side T&P valve opening
Two magnesium anode rods for more even distribution of corrosion protection and longer service life.
Hand hole cleanout for removal of accumulated lime and sediment deposits.
Drain Valve Brass drain valve.

Water connections 2.5″ (63.5mm) NPT. T&P tapping 1″ (25mm) NPT. Aquastat tapping 3⁄4″ (19mm) NPT. Certified at 300 PSI (2068 kPa) test pressure and 150 PSI 1034 (kPa) working pressure.

Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.

Sample Specification

The hot water storage tank shall be a Elbi Tank model_________with a storage capacity of not less than _____gallons/liters. The tank shall be lined with Ultonium™ vitreous enamel and shall have a bolted hand hole cleanout. The tank shall have two extruded magnesium rods installed in separate head couplings. The storage tank shall be insulated with not less than 2″ of Non-CFC foam. The entire installation shall be made in compliance with state and local codes and ordinances.

Specifications

Dimensional Data

Model
Number
Rated
Cap Gal/Ltr
A
Diam
B
Ht
C T&P
Ht.
D Top H.W.
Conn.
E
Aquas & Top
Circ. Conn.
F
Bot. Circ.
Conn.
G
Drain
Ht.
H
Cleanout
Ht.
Weight
Lbs/kg
NTN-80 80/303 24″/610mm 58 3⁄4″/1492mm 52 1⁄2″/1334mm 59 3⁄4″/1518mm 14 1⁄4″/362mm 9 1⁄4″/235mm 4 3⁄4″/121mm 7 1⁄4″/184mm 192/87
NTN-80 80/303 24″/610mm 58 3⁄4″/1492mm 52 1⁄2″/1334mm 59 3⁄4″/1518mm 14 1⁄4″/362mm 9 1⁄4″/235mm 4 3⁄4″/121mm 7 1⁄4″/184mm 192/87
NTN-120 119/450 28″/711mm 62 1⁄2″/1588mm 55 3⁄4″/1416mm 63 1⁄2″/1613mm 14 1⁄2″/368mm 9 1⁄2″/241mm 5″/127mm 7 1⁄2″/191mm 312/142
NTN-120 119/450 28″/711mm 62 1⁄2″/1588mm 55 3⁄4″/1416mm 63 1⁄2″/1613mm 14 1⁄2″/368mm 9 1⁄2″/241mm 5″/127mm 7 1⁄2″/191mm 366/166
NTN-200 200/751 32″/813mm 77″/1956mm 66″/1676mm 78″/1981mm 16 1⁄4″/413mm 11 1⁄4″/286mm 6 3⁄4″171mm 9 1⁄4″/235mm 541/245